S/FTP-CAT6A-4PR-LSZH 6 RJ45modules Pre-terminated 5M 23AWG Ice Blue Black Network Management #ZL7203034
Solid bare copperS/FTP shieldingstandard class 6A10GBase-T500MHzLSZH100% Fluke test.
  • Comply with ISO/IEC 11801-1, IEC 60603-7, ANSI/TIA-586.2-D and YD/T 926.3 standards to ensure the stability, compatibility and expansibility of the integrated wiring system.
  • The flame retardant performance of the sheath conforms to IEC 60332-1 standard, and it has excellent flame suppression ability, which can effectively prevent the spread of flame and is suitable for environments requiring high safety.
  • The double-layer shielding structure can effectively shield interference and prevent signal crosstalk generated by neighboring equipment, thus ensuring the integrity of data transmission, and is especially suitable for network deployment in complex electromagnetic environment.
  • Pre-termination design is adopted, and the termination work has been completed before leaving the factory, which greatly shortens the construction time, reduces the complexity of field operation and reduces the quality problems caused by human errors.
S/FTP-CAT6A-4PR-LSZH 12 RJ45modules Pre-terminated 5M 23AWG Ice Blue Black Network Management #ZL7203035
Solid bare copperS/FTP shieldingstandard class 6A10GBase-T500MHzLSZH100% Fluke test.
  • Comply with ISO/IEC 11801-1, IEC 60603-7, ANSI/TIA-586.2-D and YD/T 926.3 standards to ensure the stability, compatibility and expansibility of the integrated wiring system.
  • The flame retardant performance of the sheath conforms to IEC 60332-1 standard, and it has excellent flame suppression ability, which can effectively prevent the spread of flame and is suitable for environments requiring high safety.
  • The double-layer shielding structure can effectively shield interference and prevent signal crosstalk generated by neighboring equipment, thus ensuring the integrity of data transmission, and is especially suitable for network deployment in complex electromagnetic environment.
  • Pre-termination design is adopted, and the termination work has been completed before leaving the factory, which greatly shortens the construction time, reduces the complexity of field operation and reduces the quality problems caused by human errors.
S/FTP-CAT6A-4PR-LSZH 12 RJ45 crystal heads Pre-terminated 5M 26AWG Ice Blue Black Network Management #ZL7203038
Multi-strandedS/FTP shieldingstandard category 6A10GBase-T500MHzLSZH100% Fluke test.
  • Comply with ISO/IEC 11801-1, IEC 60603-7, ANSI/TIA-586.2-D and YD/T 926.3 standards to ensure the stability, compatibility and expansibility of the integrated wiring system.
  • The flame retardant property of the sheath conforms to IEC 60332-1 standard, has excellent flame retardant property, and is suitable for environments requiring high safety.
  • The double-layer shielding structure can effectively shield interference and prevent signal crosstalk generated by neighboring equipment, thus ensuring the integrity of data transmission, and is especially suitable for network deployment in complex electromagnetic environment.
  • Pre-termination design is adopted, and the termination work has been completed before leaving the factory, which greatly shortens the construction time, reduces the complexity of field operation and reduces the quality problems caused by human errors.
S/FTP CAT6A 4PR LSZH 24 RJ45 crystal head Pre-terminated 5M 26AWG Ice Blue Black Network Management #ZL7203039
Multi-strandedS/FTP shieldingstandard category 6A10GBase-T500MHzLSZH100% Fluke test.
  • Comply with ISO/IEC 11801-1, IEC 60603-7, ANSI/TIA-586.2-D and YD/T 926.3 standards to ensure the stability, compatibility and expansibility of the integrated wiring system.
  • The flame retardant property of the sheath conforms to IEC 60332-1 standard, has excellent flame retardant property, and is suitable for environments requiring high safety.
  • The double-layer shielding structure can effectively shield interference and prevent signal crosstalk generated by neighboring equipment, thus ensuring the integrity of data transmission, and is especially suitable for network deployment in complex electromagnetic environment.
  • Pre-termination design is adopted, and the termination work has been completed before leaving the factory, which greatly shortens the construction time, reduces the complexity of field operation and reduces the quality problems caused by human errors.